 V23826-H18-C13/C313 AC/AC TTL (5V/3.3V) V23826-H18-C53/C353 DC/DC (5V/3.3V) V23826-H18-C63/C363 AC/AC PECL (5V/3.3V) V23826-H18-C73/C373
AC/DC (5V/3.3V)
Single Mode 1300 nm 622 MBd ATM 1x9 Transceiver
Preliminary
Dimensions in (mm) inches
View Z
(Lead cross section and standoff size)
(9.79 max) .385 max (2) .080
Optical Centerline
(8.6 max) .338 max
9x (0.8 0.1)
(0.63 0.2) .025 .008
(1 0.1) .04 .004
.032 .004 4.675 .184
(3.3 0.2) .13 .008
PC board
(3.8 max) (0.35 0.1) .150 max .014 .004
(0.6 0.1) .024 .004 (0.460.05) .018.002 (1.4 -0.05) (2.8 max) .055 -.002 .110 max
q q
(2.54) .100 Cutout 20.32 .800
Z
123456789
(25.25 0.05) .994 .002 20.32 .800
Rx Top view 2.05 .079 Tx 12.7 .500 (1.9 0.1) 2x .075 .004 (15.88 0.5) .625 .020
q q q q q q q
(2.54) .100
20.32 .800 Footprint
A
2.5 .098 (38.6 0.15) 1.52 .006
(11 max) .433 max
* * * *
Wave solderable and washable with process plug inserted For distances of up to 15 km on single mode fiber Industry standard multisource footprint A special multimode-only version available on request
Absolute Maximum Ratings Exceeding any one of these values may destroy the device immediately. FEATURES * Compliant with existing standards * Meets mezzanine standard height of 9.8 mm * Compact integrated transceiver unit with - MQW laser diode transmitter - InGaAs PIN photodiode receiver - Duplex SC receptacle * Class 1 FDA and IEC laser safety compliant * Single power supply (5 V or 3.3 V) * Signal detect indicator (PECL and TTL versions) * PECL differential inputs and outputs * Process plug included
Semiconductor Group
Package Power Dissipation(1) ..................................................................... 1.5 W Supply Voltage (VCC-VEE) 5 V .......................................................6 V 3.3 V ....................................................4 V Data Input Levels (PECL)..................................................... VCC-0.5 V Differential Data Input Voltage.......................................................2.5 V Operating Ambient Temperature......................................... 0 to 70C Storage Ambient Temperature .......................................-40C to 85C Soldering Conditions Temp/Time (MIL -STD 883C, Method 2003) ........................................250C/5.5s
Note 1. For VCC-VEE (min., max.). 50% duty cycle. The supply current does not include the load drive current of the receiver output.
AUGUST 1998
DESCRIPTION The Siemens single mode ATM transceiver complies with the ATM Forum's Network Compatible ATM for Local Network Applications document and ANSI's Broadband ISDN--Customer Installation Interfaces, Physical Media Dependent Specification, T1.646-1995. ATM was developed to facilitate solutions in multimedia applications and real time transmission. The data rate is scalable, and the ATM protocol is the basis of the broadband public networks being standardized in the International Telecommunications Union (ITU), the former International Telegraph and Telephone Consultative Committee (CCITT). ATM can also be used in local private applications. The Siemens single mode ATM transceiver is a single unit comprised of a transmitter, a receiver, and an SC receptacle. This design frees the customer from many alignment and PC board layout concerns. The module is designed for low cost WAN applications. It can be used as the network end device interface in workstations, servers, and storage devices, and in a broad range of network devices such as bridges, routers, and intelligent hubs, as well as wide area ATM switches. This transceiver operates at 622.080 Mbits per second from a single power supply (+5 Volt or 3.3 Volt). The full differential data inputs and outputs are PECL compatible. Functional Description of 1x9 Pin Row Transceiver This transceiver is designed to transmit serial data via single mode cable. Functional Diagram
Automatic Shut-Down
LEN TD TD Laser Coupling Unit e/o
3. DC/DC Transceiver Standard PECL inputs and outputs Tx and Rx are DC coupled. 4. AC/AC PECL Transceiver Tx and Rx are AC coupled. Tx has differential 100 load. Signal Detect is PECL compatible. The transmitter contains a laser driver circuit that drives the modulation and bias current of the laser diode. The currents are controlled by a power control circuit to guarantee constant output power of the laser over temperature and aging. The power control uses the output of the monitor PIN diode (mechanically built into the laser coupling unit) as a controlling signal, to prevent the laser power from exceeding the operating limits. Single fault condition is ensured by means of an integrated automatic shutdown circuit that disables the laser when it detects transmitter failures. A reset is only possible by turning the power off, and then on again. The DC/DC transceiver contains a data input monitor, that switches the transmitter off when Data Input receives at a continuously low level. The transceiver contains a supervisory circuit to control the power supply. This circuit makes an internal reset signal whenever the supply voltage drops below the reset threshold. It keeps the reset signal active for at least 15 milliseconds after the voltage has risen above the reset threshold. During this time the laser is inactive. TECHNICAL DATA The electro-optical characteristics described in the following tables are only valid for use under the recommended operating conditions. Recommended Operating Conditions
Parameter Ambient Temperature Power Supply Voltage Supply Current(1) Transmitter 3.3 V 5V 3.3 V 5V VIH-VCC -1165 VIL-VCC V',)) -1810 300 ICC Symbol TAMB Min. 0 3.3 5 4.75 Typ. Max. 70 3.5 5.25 230 250 -880 -1475 800 mV mA Units C V
VCC-VEE 3.1
Laser Driver Power Control
Monitor
Laser
o/e Single Mode Fiber RX Coupling Unit o/e
RD RD SD
Receiver
The receiver component converts the optical serial data into PECL compatible electrical data (RD and RDnot). The Signal Detect (SD, active high) shows whether an optical signal is present. The transmitter converts electrical PECL compatible serial data (TD and TDnot) into optical serial data. The following versions are available: 1. AC/DC Transceiver Tx is AC coupled with differential 100 load. Rx has standard PECL output and is DC coupled. 2. AC/AC TTL Transceiver Tx and Rx are AC coupled. Tx has differential 100 load. Signal Detect is TTL compatible.
Semiconductor Group
Data Input High Voltage DC/DC Data Input Low Voltage DC/DC Data Input Differential Voltage(2) AC/DC, AC/AC TTL, AC/AC PECL Input Data Rise/Fall Time 10%-90% Receiver
tR, tF
100
1300
ps
Input Center Wavelength C
Note
1270
1355
nm
1. For VCC-VEE (min., max.) 50% duty cycle. The supply current does not include the load drive current of the receiver output. 2. Peak-to-peak voltage of one input.
V23826-H18-C13/C53/C63/C73, Single Mode 1300 nm 622 MBd ATM 1x9 Trx
2
Transmitter Electro-Optical Characteristics
Transmitter Launched Power (Average)(1) Center Wavelength Spectral Width (RMS) Relative Intensity Noise Extinction Ratio (Dynamic) Reset Threshold(2) Out(2) Reset Time Symbol Min. Typ. Max. Units PO C RIN ER VTH tRES ED 15 8.2 2.7 22 35 -15 1274 -11 -8 dBm
LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC 825-1 and FDA 21 CFR 1040.10 and 1040.11. The laser Class 1 is guaranteed within the Absolute Maximum Ratings. Caution The use of optical instruments with this product will increase eye hazard! Usage Restrictions The optical ports of the modules should be terminated with an optical connector or with a dust plug.
Note Failure to adhere to the above restrictions could result in a modification that is considered an act of "manufacturing," and will require, under law, recertification of the modified product with the U.S. Food and Drug Administration (ref. 21 CFR 1040.10 (i)).
1355 nm 2.5 -120 dB/Hz dB V ms
Eye Diagram(3)
Notes
1. Into single mode fiber, 9 m diameter. 2. Laser power is shut down if power supply is below VTH and switched on if power supply is above VTH after tRES. 3. Transmitter meets ANSI T1E1.2, SONET OC-12, and ITU G.957 mask patterns.
Laser Data
Wavelength 1300 nm less than 2 mW less than 180 W 4
Receiver Electro-Optical Characteristics
Receiver Sensitivity (Average Power)(1) Saturation (Average Power) Signal Detect Assert Level(2) Signal Detect Deassert Level(3) Signal Detect Hysteresis Symbol PIN PSAT PSDA PSDD PSDA- PSDD tDAS VOL-VCC VSDL VSDH VDIFF tR, tF ARL 12 2 0.5 0.9 375 ps dB -1950 -38 1.5 100 350 dB s -8 -28 Min. Typ. Max. -30 -28 Units dBm
Total output power (as defined by IEC: 50 mm aperture at 10 cm distance) Total output power (as defined by FDA: 7 mm aperture at 20 cm distance) Beam divergence
Required Labels
FDA
Complies with 21 CFR 1040.10 and 1040.11
IEC
Class 1 Laser Product
Signal Detect Assert Time tASS Signal Detect Deassert Time Output Low Voltage(4) Output High Voltage(4) Signal Detect Output Voltage AC/AC TTL(5) Low High
Laser Emission
-1600 mV -720 0.5 V VOH-VCC -1025
Indication of laser aperture and beam
Data Output Differential Voltage(6) Output Data Rise/Fall Time, 20%-80% Return Loss of Receiver
Notes
1. Minimum average optical power at which the BER is less than 1x10E-12 or lower. Measured with a 223-1 NRZ PRBS as recommended by ANSI T1E1.2, SONET OC-12, and ITU G.957 . 2. An increase in optical power above the specified level will cause the SIGNAL DETECT output to switch from a Low state to a High state. 3. A decrease in optical power below the specified level will cause the SIGNAL DETECT to change from a High state to a Low state. 4. DC/DC, AC/DC for data DC/DC, AC/DC, AC/AC PECL for Signal Detect PECL compatible. Load is 50 into VCC -2 V for data, 500 to V(( for Signal Detect. Measured under DC conditions. For dynamic measurements a tolerance of 50 mV should be added. VCC=3.3 V/5 V. 5. Max. output current high: -0.4 mA (drive current) low: +2.0 mA (sink current) 6. AC/AC for data. Load 50 to GND or 100 differential. For dynamic measurement a tolerance of 50mV should be added.
Semiconductor Group V23826-H18-C13/C53/C63/C73, Single Mode 1300 nm 622 MBd ATM 1x9 Trx
3
Pin Description
Pin Name RxVEE RD RDn SD RxVCC TxVCC TDn TD TxVEE Case Tx Ground Support Power Supply Mech. Support RX Signal Detect Rx 3.3 V/5 V Tx 3.3 V/5 V Tx Input Data PECL Input PECL Output active high Power Supply Rx Ground Rx Output Data Level / Logic Power Supply PECL Output Pin# 1 2 3 4 5 6 7 8 9 S1/2 Inverted transmitter input data Transmitter input data Negative power supply, normally ground Support stud (floating) Description Negative power supply, normally ground Receiver output data Inverted receiver output data High level on this output shows there is an optical signal. Positive power supply, 3.3 V/5 V
Regulatory Compliance
Feature Electrostatic Discharge (ESD) to the Electrical Pins Immunity: Electrostatic Discharge (ESD) to the Duplex SC Receptacle Immunity: Radio Frequency Electromagnetic Field Standard MIL-STD 883C Method 3015.4 EN 61000-4-2 IEC 1000-4-2 EN 61000-4-3 IEC 1000-4-3 Comments Class 1 (>1000 V) Discharges of 15kV with an air discharge probe on the receptacle cause no damage. With a field strength of 10 V/m rms, noise frequency ranges from 10 MHz to 1 GHz. No effect on transceiver performance between the specification limits.
APPLICATION NOTE Single Mode 1300 nm 622 MBd ATM 1x9 Transceiver, DC/DC Version
VCC SerDes 5 V / 3.3 V R11
TXGND
9
VCC TX+
TxD Laser Driver
8
C6
TxD
7
C7 R8
R10
R7
ECL/PECL Driver TX-
VCCTx
6 C1
L1 VCC 5 V / 3.3 V L2 Serializer/ Deserializer C3
Siemens Transceiver V23826-H18-C63/363 DC/DC Option
VCCRx
5 C2
C1/2/3 = 4.7 F C4/5/6/7 = 10 nF L1/2 = 1 H R1/2/10/11 = 82 (5 V) = 127 (3.3 V)
(depends on SerDes chip used)
Signal Detect
SD
4
SD to upper level R1 C4 R9 R2
R3/4/7/8
= 127 (5 V) = 82 (3.3 V)
PreAmp
Limiting Amplifier
RD-
RxD
3
RDReceiver PLL etc.
(depends on SerDes chip used)
RD+
RxD
2
C5
RD+ R3 R4
= 300 (5 V) = 150 (3.3 V) R9 = 500 (5 V) = 270 (3.3 V) Place R1/2/3/4 close to SerDes chip Place R7/8/10/11 close to Siemens Transceiver R5/6
Values of R1/2/3/4 may vary as long as proper 50 termination to VEE or 100 differential is provided. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module VCCRx/VCCTx.
Semiconductor Group
The transceiver contains an automatic shutdown circuit. Reset is only possible if the power is turned off, and then on again. (VCCTx switched below VTH). Application Board available on request.
V23826-H18-C13/C53/C63/C73, Single Mode 1300 nm 622 MBd ATM 1x9 Trx
4
R5
R6
RxGND
1
APPLICATION NOTE Single Mode 1300nm 622 MBd ATM 1x9 Transceiver, AC/DC Version
VCC SerDes 5 V / 3.3 V
TXGND
9
VCC TX+ ECL/PECL Driver
TxD Laser Driver 100 TxD
8
7 R7 R8
TX-
VCCTx
6 C1
L1 VCC 5 V / 3.3 V L2 Serializer/ Deserializer
Siemens Transceiver V23826-H18-C13/313 AC/DC Option
Signal Detect
VCCRx
5 C2
C3
SD
4
SD to upper level R1 C4 R9 R2
PreAmp
Limiting Amplifier
RD-
RxD
3
RDReceiver PLL etc.
RD+
RxD
2
C5
RD+ R3 R4
R5
C1/2/3 C4/5 L1/2 R1/2
= = = = = R3/4 = =
4.7 F 10 nF 1 H 82 for 5 V (depends on SerDes chip used) 127 for 3.3 V (depends on SerDes chip used) 127 for 5 V (depends on SerDes chip used) 82 for 3.3 V (depends on SerDes chip used)
Values of R1/2/3/4 may vary as long as proper 50 termination to VEE or 100 differential is provided. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module VCCRx/VCCTx.
Semiconductor Group
R6
5
RxGND
1
R5/6 = 300 (5 V) = 150 (3.3 V) R9 = 500 (5 V) = 270 (3.3 V) Place R1/2/3/4/7/8 close to SerDes chip R7/8 depends on SerDes chip
The transceiver contains an automatic shutdown circuit. Reset is only possible if the power is turned off, and then on again. (VCCTx switched below VTH). Application Board available on request.
V23826-H18-C13/C53/C63/C73, Single Mode 1300 nm 622 MBd ATM 1x9 Trx
APPLICATION NOTE Single Mode 1300nm 622 MBd ATM 1x9 Transceiver, AC/AC TTL and AC/AC PECL Versions
VCC SerDes 5 V / 3.3 V
TXGND
9
VCC TX+ ECL/PECL Driver
TxD Laser Driver 100 TxD
8
7 R7 R8
TX-
VCCTx
6 C1
L1 VCC 5 V / 3.3 V L2 Serializer/ Deserializer
Siemens Transceiver V23826-H18-C53/353 V23826-H18-C73/373 AC/AC SD TTL, PECL Option
Signal Detect
VCCRx
5 C2
C3
VCC
R1
SD
4
R9 PreAmp Limiting Amplifier RDRxD 3 R3 RDReceiver PLL etc. RD+ R4
RD+
RxD
2
RxGND
1
C1/2/3 L1/2 R9
= 4.7 F = 1 H = 500 (5 V PECL) = 270 (3.3 V PECL) = no resistor (TTL) R1/2/3/4 depends on SerDes chip (optional) R7/8 depends on SerDes chip
The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module VCCRx/VCCTx.
The transceiver contains an automatic shutdown circuit. Reset is only possible if the power is turned off, and then on again. (VCCTx switched below VTH). Application Board available on request.
Siemens Microelectronics, Inc. * Optoelectronics Division * 19000 Homestead Road * Cupertino, CA 95014 USA Siemens Semiconductor Group * Fiber Optics * Wernerwerkdamm 16 * Berlin D-13623, Germany Siemens K.K. * Fiber Optics * Takanawa Park Tower * 20-14, Higashi-Gotanda, 3-chome, Shinagawa-ku * Tokyo 141, Japan www.smi.siemens.com/opto.html (USA) * www.siemens.de/Semiconductor/products/37/376.htm (Germany)
R2
SD to upper level


▲Up To Search▲   

 
Price & Availability of V23826-H18-C353

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X